home page

Milwaukee has a wide assortment of pH ORP, Conductivity and other specialty sensors to meet all your specific requirements.  Finding the right electrode for a specific application is a very important task and in order to solve this selection problem it is important to consider the following:

pH & ORP Electrodes & Probes

1. Glass body electrode versus Epoxy (plastic) body electrode: Glass body electrodes stand higher temperatures (typically 100 C against 80 C for plastic) and are more resistant to corrosive chemicals and solvents.  They are easier to clean and are available in different shapes depending on the application.  On the other hand plastic body electrodes are more rugged and the glass bulb is better protected.

2. Gel filled electrodes versus refillable electrodes: refillable electrodes last longer since electrolyte can be changed for repeated usage.  The response is faster due to a greater outflow of electrolyte into the sample and therefore less likely to clog. Gel filled electrodes require less maintenance and resist to higher pressure.

3. Double reference junction versus Single junction reference: Double junction reference electrodes have a longer live and protects the sample measured from silver contamination from the electrolyte.  The Silver wire is more protected and therefore gets less contaminated. The single junction electrodes normally costs less and is ideal for general purpose applications

4. Conic shaped versus Sphere shaped: The conic shaped electrode is easier to clean and to maintain (ideal for applications such as dairy). Has a more rugged tip and therefore ideal for penetration.  The sphere-shaped has a faster response time due to the larger surface area on the bulb.

 

pH, ORP, Conductivity, Dissolved Oxygen Electrodes & Probes

Milwaukee has a wide assortment of pH, ORP, Conductivity and other specialty sensors to meet all your specific
requirements.
Finding the right electrode for a specific application is a very important task and In order to solve this
selection problem it is important to consider the following: electrode body, reference construction and
junction.
Below you will find a list of Milwaukee electrodes and probes. Special electrodes for specific applications
can also be manufactured upon request.

MA811/2 Conductivity probe with 2m cable    $72.00
MA812/2 Conductivity probe with 2m cable   $72.00
MA812D/1 EC/TDS probe with DIN connector and 1 m cable   $72.00
MA814D/1 4-ring EC probe with DIN connector and 1 m (3.3’) cable  $159.50
MA815/2 Conductivity probe for SMS315 with 2 m cable   $86.13
MA816/2 Conductivity probe for SMS415 with 2 m cable   $86.13
MA831R Temperature probe   $83.62
MA840 Polarographic D.O. probe with 3 meter cable  $280.38
MA850 pH/EC/TDS spare probe with 1 m cable   $120.59
MA851D/1 pH/EC/TDS/Temp amplified probe with DIN connector, 1 m (3.3’) cable   166.34
MA911B/1 Double junction, gel filled pH electrode with BNC connector, 1 m cable   $84.88
MA913B/3 Combined Epoxy pH electrode, BNC connector, for swimming pool, 3 m cable   90.52
MA914BR/1 pH/Temp amplified probe with BNC & RCA connectors, 1 m cable   203.31
MA915B/2 Combined glass pH electrode for agriculture with BNC connector, 2 m cable   $123.10
MA915B/3 Combined glass pH electrode for agriculture with BNC connector, 3 m cable  $123.10
MA916B/1 Combined glass pH electrode, refillable with BNC connector, 1 m cable   $151.30
MA916B/3 Combined glass pH electrode, refillable with BNC connector, 3 m cable   $156.94
MA917B/1 Glass body, double junction refillable pH electrode with BNC connector, 1 m cable $208.32
MA918B/1 Combined glass pH electrode, refillable with 3 diaphragm with BNC, 1 m cable    $195.16
MA921B/1 Double junction, gel filled ORP electrode with platinum sensor, BNC, 1 m cable    $88.64
MA921B/2 Double junction, gel filled ORP electrode with platinum sensor, BNC, 2 m cable   $88.64
MA923D/1 pH/ORP/Temp amplified probe with DIN connector, 1 m cable   $307.95
MA923B/3 Epoxy electrode redox, BNC connector, for swimming pool, 3 m cable $93.65

secure order page