Mi180 pH / ORP / Conductivity / TDS / NaCl / Temperature Laboratory Bench
Meter
Mi180
measures 6 different parameters: pH, ORP, EC, TDS (Total Dissolved Solids),
percentage of NaCl and temperature in a variety of ranges.
pH calibration can be performed in 3 points selectable between 7 memorized
buffers, to provide a very accurate calibration curve even when testing
different samples, where very wide differences in pH can be found.
The
auto-ranging feature for EC and TDS measurements automatically sets the
resolution suitable to the tested sample.
All measurements can be temperature compensated at 20 or 25°C and the
compensation coefficient is selectable by the user.
The automatic temperature compensation can also be disabled for measuring
the actual conductivity value. The stability indicator on the LCD ensures
accuracy. Conductivity readings are performed with the 4-ring probe supplied
with the meter.
The GLP feature allows users to store and recall data on system status. PC
compatible through an RS232 port or USB. |
 |
|
SPECIFICATIONS |
|
pH
Range |
-2.00
to 16.00 pH; -2.000 to 16.000 pH |
|
mV
Range |
±699.9 mV; ±2000
mV |
|
EC
Range |
0.00 to 29.99
µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0
to 200.0 mS/cm; up to 500.0 mS/cm uncompensed EC* |
|
TDS
Range |
0.0 to 14.99 mg/l
(ppm); 15.0 to 149.9 mg/l (ppm); 150 to 1499 mg/l (ppm); 1.50 to 14.99
g/l (ppt); 15.0 to 100.0 g/l (ppt); up to 400.0 g/l actual TDS* (with
0.80 factor) |
|
NaCl
Range |
0.0
to 400.0% |
|
Temp
Range |
-20.0 to 120.0°C /
-4.0 to 248.0°F |
|
pH
Resolution |
0.01 pH; 0.001 pH |
|
mV
Resolution |
0.1 mV; 1 mV |
|
EC
Resolution |
0.01 µS/cm; 0.1
µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm; |
|
TDS
Resolution |
0.01 mg/l; 0.1 mg/l;
1.0 mg/l; 0.01 g/l; 0.1 g/l |
|
NaCl
Resolution |
0.1% |
|
Temp
Resolution |
0.1°C / 0.1°F |
|
pH
Accuracy |
±0.01 pH; ±0.002 pH |
|
mV
Accuracy |
±0.2 mV; ±1 mV |
|
EC
Accuracy |
±1% of reading ±(0.05
µS/cm or 1 digit) |
|
TDS
Accuracy |
±1% of reading ±(0.03
ppm or 1 digit) |
|
NaCl
Accuracy |
±1% of reading |
|
Temp
Accuracy |
±0.4°C / ±0.8°F |
|
Rel
mV Offset |
±2000 mV |
|
pH
Calibration |
1, 2 or 3 points
calibration, with 7 memorized buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18,
10.01 and 12.45) |
|
EC
Calibration |
1 point slope
calibration with 6 memorized solutions: (84 µS/cm, 1413 µS/cm, 5.00 mS/cm,
12.88 µS/cm, 80.0 µS/cm, 111.8 mS/cm) |
|
NaCl
Calibration |
1 point, with MA9066
solution |
|
Temp
Calibration |
2 point, at 0 and
50°C / 32 and 122°F |
|
Temperature Compensation |
automatic or manual,
from -20.0 to 120.0°C / -4.0 to 248.0°FF |
|
Temperature Coefficient |
selectable from 0.00
to 6.00%/°C (EC and TDS only) |
|
pH
Electrodes & Temp Probe |
MA917B/1 & MA831R
(included) |
|
TDS
Factor |
0.40 to 0.80 (default
value is 0.50) |
|
Log
on demand |
up to 50 samples on
each range (pH, mV, EC, TDS, NaCl) |
|
GLP |
last pH, EC, NaCl
calibration data |
|
PC
Interface |
RS232 / USB Opto-isolated |
|
Environment |
0 to 50°C / 32 to
122°F; max RH 95% |
|
Power
supply |
12 VDC power
adapter (included) |
|
Dimensions |
230 x 160 x 95 mm |
|
Weight |
0.9 kg |
|
|
ACCESSORIES |
|
MA9001 |
pH
1.68 buffer solution, 230 mL bottle |
|
MA9004 |
pH 4.01 buffer
solution, 230 mL bottle |
|
MA9006 |
pH 6.86 buffer
solution, 230 mL bottle |
|
MA9007 |
pH 7.01 buffer
solution, 230 mL bottle |
|
MA9009 |
pH 9.18 buffer
solution, 230 mL bottle |
|
MA9010 |
pH 10.01 buffer
solution, 230 mL bottle |
|
MA9012 |
Refilling
solution for pH electrode, 230 mL bottle |
|
MA9060 |
12880 µS/cm
calibration solution, 230 mL bottle |
|
MA9061 |
1413 µS/cm
calibration solution, 230 mL bottle |
|
MA9063 |
84 µS/cm calibration
solution, 230 mL bottle |
|
MA9065 |
111.8 mS/cm
calibration solution, 230 mL bottle |
|
MA9066 |
100% NaCl calibration
solution, 230 mL bottle |
|
MA9069 |
5000 µS/cm solution,
230 mL bottle |
|
MA9310 |
12 VDC Adapter, 220 V |
|
MA9311 |
12 VDC Adapter, 110 V |
|
MA917B/1 |
Glass body, double
junction refillable pH electrode |
|
MA813D/1 |
Conductivity/Temperature probe with DIN connector and 1 m cable
|
|
MA921B/1 |
Double junction, gel
filled ORP electrode |
|
MA831R |
Temperature probe |
MA9350
|
RS232 connection
cable with 2 m cable |
|
Mi5200 |
Application Software |
| |
|
ORDERING INFORMATION |
|
Mi180 is supplied complete with:
• MA917B/1 pH Electrode
• MA813D/1 EC/TDS/NaCl/Temperature probe
• MA831R Temperature Probe
• MA9315 Electrode Holder
• M10004 pH 4.01 Sachet Buffer Solution
• M10007 pH 7.01 Sachet Buffer Solution
• M10010 pH 10.01 Sachet Buffer Solution
• M10016 Sachet Electrode Cleaning Solution
• Mi5200 Application Software
• MA9350 RS232 connection cable with 2 meters cable
• Graduate Pipet, 12 VDC Adapter & Instruction manual |
|