home page

Products > Controllers > SMS125
Instruction Manual
 
Instruction Manual
Print
Print

SMS125 Smart pH / ORP Controller

With Milwaukee's Smart controllers you can monitor and control pH and/or ORP levels directly in your aquarium. All our controllers work with a 12 VDC adapter and can be hanged above your aquarium. The meters have a user selectable set point and a visual LED alarm that is active when the reading is higher (for pH) or lower (for mV) than the set point. Also the instruments are supplied with a power plug for CO2 or ozone dosing. With each Milwaukee Smart controller your aquarium will have the individual attention that it needs.

Monitor & control pH & ORP levels with 1 single unit. Dual set points, for pH(5.5 to 9.5) and for ORP (0 to 600 mV), adjustable with knobs. Simply attach 1 solenoid valves and pump to the plug socket supplied to dose CO2 and ozone as required. The SMS125 has a Visual Led alarms.

SMS125

MA911B/1
Double junction, gel filled pH electrode with BNC connector, with 1 meter cable

Calibration, Maintenance & Cleaning Solutions
Choose from our wide selection of calibration, maintenance and cleaning solutions.
SPECIFICATIONS
Range 0.00 to 14.00 pH; ±1000 mV (ORP)
Resolution 0.01 pH; 1 mV (ORP)
Accuracy ±0.2 pH; ±5 mV (ORP)
pH set point 4 to 8 pH
ORP set point -200 to 600 mV
pH Alarm active when measurement is
higher than the set points
ORP Alarm active when measurements are
lower than set points
pH Output Power Socket active when measurement is
higher than set point
ORP Output Power Socket active when the measurement is
lower than set point
pH Electrode MA911B/2 (included)
ORP Electrode MA921B/2 (included)
Environment 0 to 50°C / 32 to 122°F; max RH 95%
Power Supply 12 VDC power adapter (included)
Power Drivers 115VAC, 2A, 60Hz or 230VAC, 1A, 50Hz
Dimensions 145 x 80 x 40 mm
Weight 220 g (meter only)

 

 
 
 
 
ACCESSORIES
MA911B/1 Double junction, gel filled pH electrode with 1 m cable
MA921B/2 ORP Electrode with BNC connector and 2 m cable
M10004B pH 4.01 buffer solution 20 mL
sachet (25 pcs)
M10007B pH 7.01 buffer solution 20 mL
sachet (25 pcs)
M10010B pH 10.01 buffer solution 20 mL
sachet (25 pcs)
MA9015 Electrode storage solution 20 mL
sachet (25 pcs)
M10000B Electrode rinse solution 20 mL
sachet (25 pcs)
MA955 Solenoid valve with 1.5 m cable
 
ORDERING INFORMATION
SMS125 is supplied complete with 12 VDC adapter, power plug socket for ozone dosing, MA911B/2 pH electrode, MA921B/2 ORP electrode, 20 mL pH7.01 sachet of calibration solution, calibration screwdriver and instructions.